Read a certificate of analysis in this order: match the lot code and sample description to your shipment, then check the method, the unit, the reporting limit, the uncertainty and the laboratory's accreditation scope. A pass or fail verdict needs a stated limit and decision rule. For banned substances the limit must sit at or below the reference point.
Start with identity. A report that does not belong to your lot proves nothing about your lot. Compare the sample ID, the lot code and the production date with the carton label and the packing list. Then work down the fields in the table. Each field has a mismatch that should make you stop and ask the supplier or the laboratory.
| Field | What to check | Mismatch signal |
|---|---|---|
| Sample ID and lot code | Equals the carton lot code and the packing list | Different or missing code |
| Sample description | Species, form (raw, cooked, glazed or deglazed), prepared as the specification assumes | Laboratory tested a different form |
| Method | A named standard and edition, such as EN ISO 6579-1 | In-house method with no validation statement, or screening only |
| Result and unit | Unit matches the limit you apply | cfu/g against per 25 g; µg/kg against mg/kg |
| Reporting limit | At or below the limit you check | Reporting limit above the reference point |
| Uncertainty | Stated for quantitative results | Missing on an accredited method |
| Decision rule | Stated wherever a pass or fail is given | Verdict with no rule |
| Accreditation | ISO/IEC 17025 scope covers this test | Test outside the scope |
| Dates | Sampling, receipt, analysis and report dates | Analysis before production, or long after storage |
Regulation (EC) 2073/2005 names the reference methods for its microbiological criteria. A report that cites a different method should explain why. The methods named in Annex I are:
Units decide what a number means. Microbiology results appear as cfu/g, MPN/g or per 25 g. Residue results appear in µg/kg, and a slip to mg/kg changes the figure by a factor of one thousand. Always convert to the unit of the limit before you compare.
The reporting limit is the lowest level the laboratory reports for that test. Ask the laboratory how it set it. If the reporting limit is above the value you are checking, a result of not detected tells you nothing about that value. Regulation (EU) 2019/1871 sets reference points for unauthorised substances. A report for those substances should show a reporting limit at or below them.
This is general information. The regulation text we read is the UK-retained copy, so confirm the current values with your customs broker and the competent authority.
IFST guidance makes four points that apply to every report. No analytical result is absolute, and uncertainty affects both identification and quantification. Screening results often need confirmation. A laboratory accredited to ISO 17025:2017 must make you aware of the analytical uncertainty. And a pass or fail statement should say how conservatively uncertainty was handled, usually through a guard band. If a report says pass and gives no rule, ask which limit and which rule the verdict used.
IFST also advises checking that the sample was prepared the way your specification assumes, and that the laboratory used your definition. For frozen seafood this means raw or cooked, and glazed or deglazed. See how EU buyers handle the net weight and glaze question for shrimp.
File the report with the other papers for the shipment. The EU shipment readiness checklist and the pre-shipment inspection guide show where it fits.
Match the lot code and sample description to your shipment. Then check the method, the unit, the reporting limit and the uncertainty. Confirm that the method is the one the regulation names and that the laboratory's accreditation covers it.
A result of not detected only means the level is below the reporting limit. If that limit is higher than the value you are checking, the result cannot show compliance. Ask the laboratory how it set the limit. Request the answer in writing and keep it with the lot file for later audits.
Every result carries uncertainty. IFST notes that an accredited laboratory must make you aware of it, and that a pass or fail verdict should state how uncertainty was handled, often through a guard band. A verdict without that statement is incomplete.
Look for a lot code or date that differs from the carton, units that do not fit the legal limit, a method that is not named, or accreditation that does not cover the test. Request the full report rather than a summary page, and ask the supplier to explain any gap.
Send TBESFOOD your specification: product, form, size, packing and destination. We will reply with a quote and a timeline.
Read next
Our team is available to answer your questions. Please fill out the form and we'll be in touch shortly.
TBESFOOD COMPANY LIMITED
A member of TBES Group
Head Office: 2nd Floor, 81 Cach Mang Thang 8 Street, Ben Thanh Ward, Ho Chi Minh City, Vietnam
Branch: 62/29C Lam Van Ben Street, Tan Hung Ward, Ho Chi Minh City, Vietnam
Factory: Lot C1.1, Cau Cang Phuoc Dong Industrial Zone, Hamlet 5, Phuoc Dong Commune, Can Duoc District, Long An Province
Lao Factory: Lao Yeast Factory, Ban Naphasouk, Xaythany District, Vientiane Capital, Lao PDR
TBES FOOD PTE. LTD.
Singapore Address: 470 North Bridge Road, #05-12, Bugis Cube, Singapore 188735
Sister brands: TbesAgri frozen fruit · TBESBY brewer's yeast · Lao Yeast Factory industrial ethanol
© 2016–2026 TBESFOOD COMPANY LIMITED. All rights reserved.
EspañolPrivacyCookie settingsTBESFOOD COMPANY LIMITED, a member of TBES Group