In short

A reefer container's controller logs supply air, return air and any cargo probe readings, plus alarms and events. The standard logging interval is one hour, and the controller keeps values for more than a year. Ask for a download at discharge, because a log is hard to retrieve after the container has moved on.

What does a reefer data logger record?

Modern reefer controllers act as data loggers. According to the GDV Container Handbook, a logger records supply air and return air temperature, alarms, ambient temperatures, pre-trip inspection results and cargo probe readings. The standard logging interval for temperature is one hour. Events such as alarms and defrost cycles are saved separately from the temperature series.

The values are discrete. Depending on type and programming, each entry is a snapshot or an average over the interval. A logger therefore shows temperature at the moments when it wrote a value, and it does not draw a continuous line. Keep this in mind when you read a download. Two readings an hour apart say nothing certain about the minutes between them.

Supply air leaves the cooling unit and enters the cargo space. Return air comes back from the cargo space to the unit. For frozen cargo the two series answer different questions. Supply air shows what the unit is delivering. Return air gives a view of the air that has passed over the load. Probe readings, where fitted, add a third reference. The handbook describes these three series as the usual content of the controller log.

Why do chart recorders matter less now?

Circular chart recorders used a paper chart that ran for 31 days and usually recorded return air only. The handbook states that they are rarely fitted to new containers, because they no longer meet EU standards and are costly. A considerable share of reefers now rely only on a data logger. Controllers save measured values for more than a year, and they also record on and off times and manual interventions.

This changes what a buyer can ask for. A paper chart could be handed over at the terminal. A controller log sits inside the unit and has to be downloaded by someone with the right equipment. The handbook notes that in a claim it can be difficult to locate the container and have its logger read out. It also points out that discrete values give no quick view of the history of a shipment.

What should you request before the container sails?

Agree the temperature record in the sales contract or the booking instructions, not after arrival. The list below is a practical request set. Each item is something to ask for. It is not a promise that a given carrier offers it.

  1. The set point for the cargo, written on the booking and on the sales documents, so the log has a reference value.
  2. The container number and seal number on the invoice, packing list and bill of lading, so the right logger can be found later.
  3. Confirmation that the pre-trip inspection result is part of the log. The handbook lists it among the recorded items.
  4. A statement of who orders a download at discharge, in which format and how soon. Ask the forwarder or the carrier what they can supply.
  5. A copy of the supplier's own loading record, such as the product temperature at loading, to sit beside the carrier log.
  6. A rule for what happens if the download shows an alarm or a gap: who is notified, within what time, and which samples are kept.

How do you read a logger download?

The handbook mentions that a carrier extract exists, but it gives no step-by-step reading method. The table below is a reading frame built from the fields the handbook lists. It is an illustration of the questions to put to any download, and it carries no values.

Reading frame for a reefer controller download (illustration)
FieldWhat to look forQuestion to ask
Set pointValue recorded at the start of the voyageDoes it match the booking and the sales documents?
Supply air seriesSteady readings through the voyageAre there gaps or unexplained steps in the series?
Return air seriesReadings after loading and after any eventDoes return air follow supply air after each event?
USDA probe readings, where fittedReadings at the probe positionsDo the probes agree with return air over the voyage?
Alarms and eventsTime and type of each alarm or defrost cycleIs each alarm explained by the carrier?
On and off times, manual interventionsPower interruptions and manual changesWho changed a setting, and when?
Pre-trip inspection resultResult recorded before loadingWas it recorded, and did it pass?
Container number and date stampsStart and end dates of the fileDo they match the bill of lading?

Read the file in a fixed order. Check the container number and the dates first. Compare the set point with the contract. Then read the list of alarms and events, and match each event to the temperature series around it. An alarm followed by readings that return to the set point is a different finding from an alarm followed by a drift. Record which one you see, and keep the file in its original form.

What can a logger not tell you?

A controller log describes the air that the unit measures. It does not describe the temperature inside a carton. It does not show how the cargo was handled before loading, or after the container was unplugged on land. Because the values are discrete, a short event can fall between two entries. Treat the log as one record, to be read together with the loading record, the seal check and the physical inspection on arrival.

A logger placed in the cargo by the shipper or the buyer is a separate record from the carrier's controller log. The research behind this guide did not cover that type of device. If you plan to use one, agree in advance on the owner, the reading interval, the file format and the person who reads it, and put the agreement in writing.

How does the log fit into receiving inspection?

Authority guidance on receiving frozen food centres on simple checks. A factsheet from FSANZ says that food delivered frozen must be frozen and not partly thawed, that packaging must be intact, and that the use by date must be valid. That page gives no numeric limit for frozen product. A logger download adds the time and temperature history to those checks. Our EU shipment readiness checklist lists the documents that sit beside it. Who pays for a download, and who carries risk during the voyage, depends on the Incoterm; see our guide to FOB, CFR and CIF.

A short checklist for the day the container arrives:

  • Check the seal number and container number against the documents.
  • Read and note the set point shown on the unit.
  • Check cartons for signs of thaw, split packaging or damage.
  • Ask for the logger download the same day if anything looks wrong.
  • Keep dated photographs and retained samples with the claim file.

FAQ

What does a reefer data logger record?

It records supply air and return air temperature, alarms, ambient temperatures, pre-trip inspection results and cargo probe readings, according to the GDV Container Handbook. The standard interval for temperature is one hour, and events such as alarms and defrost are saved separately. Entries are discrete values, so the log is a series of points and not a continuous line.

How long does a controller keep its data?

The handbook states that controllers save measured values for more than a year. That period does not make retrieval easy. In a claim it can be difficult to locate the container and have its logger read out, so request the download soon after discharge and quote the container number in the request.

Can I get the temperature record for my frozen container if I did not ask before shipment?

You may be able to, but it is harder. The log sits in the container's controller, and someone with the right equipment must download it. Ask your forwarder or the carrier's agent, quote the container number and the dates, and state the reason. Next time, write the download request into the booking instructions.

Do paper chart recorders still exist?

Circular chart recorders with 31-day charts are rarely fitted to new containers, according to the handbook, because they no longer meet EU standards and are costly. Most buyers will receive a controller log and not a paper chart. Confirm with the forwarder what record the carrier provides when you make the booking.

Sources

Send the specification (product, form, size, packing and destination) to TBESFOOD for a quote and timeline. State in the request any temperature record you need with the shipment, so it can be raised with the forwarder at booking.

Let's Talk

Our team is available to answer your questions. Please fill out the form and we'll be in touch shortly.

*Please share the details of your request, and if applicable, the specific product you're interested in.

Email us

export@tbesfood.com

Call or WhatsApp

+84 932 072 978

TBESFOOD COMPANY LIMITED

A member of TBES Group

Head Office: 2nd Floor, 81 Cach Mang Thang 8 Street, Ben Thanh Ward, Ho Chi Minh City, Vietnam

Branch: 62/29C Lam Van Ben Street, Tan Hung Ward, Ho Chi Minh City, Vietnam

Factory: Lot C1.1, Cau Cang Phuoc Dong Industrial Zone, Hamlet 5, Phuoc Dong Commune, Can Duoc District, Long An Province

Lao Factory: Lao Yeast Factory, Ban Naphasouk, Xaythany District, Vientiane Capital, Lao PDR

TBES FOOD PTE. LTD.

Singapore Address: 470 North Bridge Road, #05-12, Bugis Cube, Singapore 188735

Sister brands: TbesAgri frozen fruit · TBESBY brewer's yeast · Lao Yeast Factory industrial ethanol

© 2016–2026 TBESFOOD COMPANY LIMITED. All rights reserved.

EspañolPrivacyCookie settings
FacebookEmailWhatsApp

TBESFOOD COMPANY LIMITED, a member of TBES Group